Datasheets»CUI»VMS-365 Datasheet

VMS-365 Datasheet

Download or read online CUI VMS-365 Open Frame Switching Power Supply pdf datasheet.



Page
1 of 4
next
PART NUMBER: VMS-365 series
features
·industry standard 3x5” footprint
3
·19 W/in
power density
·universal input: 90~264 V ac
·active PFC
·90% typical efficiency
·12 V auxillary fan output
·full medical and ITE safety approvals
·meets the requirements (80+) of the
Energy Star 4.0 documents and the
anticipated 90+ requirement for 2010
MODEL
output
voltage
VMS-365-12
12 V dc
VMS-365-24
24 V dc
VMS-365-48
48 V dc
ALL 12 V fan aux.
12 V dc
5 V standby
5 V dc
notes:
1. total continuous output power will not exceed 365 W forced air, 200 W witout fan
2. measured at 20MHz, twisted pair with 0.47μF ceramic and 22μF tantalum parallel capacitors
3. forced air will be sufficient to keep heat sink temperatures below 110°C at 50°C ambient operation
INPUT
parameter
conditions/description
input frequency
input voltage
input current
AC input of 90 VAC
AC input of 180 VAC
inrush current
no damage at 230 V ac cold start
power factor
when measured at full rated load and at
115 V ac / 60 Hz and 230 V ac / 50 Hz input source input will be
less than 25 Ω compliant to EN61000-3-2 for harmonic currents
leakage current
when measured per IEC 60950-1, paragraph 5.1
test voltage of 120 V ac / 60 Hz
test voltage of 230 V ac / 60 Hz
OUTPUT
parameter
conditions/description
minimum loading
efficiency
at 20% and 100% of max. rated load
at 50% of max. rated load
line regulation
at 90~264 V ac
4
load regulation
12, 24, or 48 V outputs
12 V aux. output
transient response
25% I
to I
max
start up time
rise
hold up time
notes:
4. RS+ must be connected to positive output and RS- connected to negative output
th
20050 SW 112
Ave. Tualatin, Oregon 97062
DESCRIPTION: open frame switching power supply
1
current max.
(convection)
(400 LFM forced air)
16.6 A
8.3 A
4.16 A
0.5 A
1 A
, 0.1A/μs slew rate, ±5% max. deviation, 10 ms recovery
max
phone
phone 503.612.2300 fax
1,3
2
current max.
ripple & noise
initial voltage
(mVp-p max.)
30.4 A
120 mV
15.2 A
240 mV
7.6 A
480 mV
1 A
240 mV
2 A
50 mV
min
nom
max
47
63
90
100~240
264
125
373
5
2.5
0.98
110
275
min
nom
max
0
88
90
±1
±1
±15
500
200μ
5m
16
fax 503.612.2382
1 of 4
page
12/2008
date
set-point
±3%
±3%
±3%
±15%
±5%
units
Hz
V ac
V dc
A
A
μA
μA
units
A
%
%
%
%
%
mS
S
mS

Summary of Contents

Page 1

... PART NUMBER: VMS-365 series features ·industry standard 3x5 footprint 3 ·19 W/in power density ·universal input: 90264 V ac ·active PFC ·90% typical efficiency ·12 V auxillary fan output ·full medical and ITE safety approvals ·meets the requirements (80) of the Energy Star 4.0 documents and the ...

Page 2

... PART NUMBER: VMS-365 series RELIABILITY parameter conditions/description MTBF 235K hours min convection, 300K hours typical with 400 LFM forced air (MIL-HDBK-217E-1, 75% of rated full load, 25°C ambient) PROTECTION CIRCUITS parameter conditions/description over current 150% max., auto recovery output over-voltage 125% max. (for 12, 24 short circuit the power supply will auto recover with no damage from a short on any output ...

Page 3

... PART NUMBER: VMS-365 series POWER OK The POK pin of J3 shall change from the low STATE (<400mV) to the high STATE (>4.5V) 100 500 mS after the main outputs are within the regulation limits. Conversely, the POK should be de-asserted to a low state when any of the main output voltages fall below its under-voltage threshold, or when the main power has been removed for a time sufficiently long such that the power supply operation cannot be guaranteed beyond the power-down warning time ...

Page 4

... PART NUMBER: VMS-365 series MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: open frame switching power supply phone phone 503.612.2300 fax fax 503.612.2382 page 12/2008 date ...