Datasheets»CUI»VMS-160 Datasheet

VMS-160 Datasheet

Download or read online CUI VMS-160 Open Frame Switching Power Supply pdf datasheet.



Page
1 of 3
next
PART NUMBER: VMS-160
features
·industry standard 2x4” footprint
3
·18 W/in
power density
·universal input: 90~264 V ac
·active PFC
·90% typical efficiency
·12 V auxillary fan output
·full medical and ITE safety approvals
MODEL
output
voltage
VMS-160-5
5 V dc
VMS-160-12
12 V dc
VMS-160-24
24 V dc
VMS-160-48
48 V dc
ALL 12 V fan aux.
12 V dc
notes:
1. total continuous output power will not exceed 160 W forced air (400LFM), 100 W witout fan
2. total continuous output power will not exceed 100 W forced air (400LFM), 80 W witout fan for 5 V model
3. measured at 20MHz, twisted pair with 0.47μF and 22μF parallel capacitors
INPUT
parameter
conditions/description
input frequency
input voltage
input current
AC input of 100 VAC
AC input of 200 VAC
inrush current
no damage at 230 V ac cold start
power factor
when measured at full rated load and at
115 V ac / 60 Hz and 230 V ac / 50 Hz input
source input will be less than 25 Ω
compliant to EN61000-3-2 for harmonic currents
leakage current
when measured per IEC 60950-1, paragraph 5.1
test voltage of 120 V ac / 60 Hz
OUTPUT
parameter
conditions/description
minimum loading
efficiency
at 20%, 50%, and 100% of max. rated load
(forced air ratings)
voltage adjust
line regulation
at 90~264 V ac
load regulation
5, 12, 24, or 48 V outputs
12 V aux. output
transient response
25% I
to I
max
start up time
rise
th
20050 SW 112
Ave. Tualatin, Oregon 97062
DESCRIPTION: open frame switching power supply
1,2
current max.
(convection)
16 A
8.3 A
4.16 A
2.08 A
0.5 A
, 0.1A/μs slew rate, ±5% max. deviation, 1 ms recovery
max
phone 503.612.2300 fax
phone
1,2
3
current max.
ripple & noise
initial voltage
(forced air)
(mVp-p max.)
20 A
50 mV
13.3 A
120 mV
6.66 A
240 mV
3.33 A
480 mV
0.5 A
500 mV
min
nom
max
47
63
90
100~240
264
125
373
2.5
1.25
0.98
275
min
nom
max
0
80
90
±10
±1
±1
±20
500
0.2
20
www.v-infinity.com
fax 503.612.2383
1 of 3
page
12/2009
date
set-point
±1%
±1%
±1%
±1%
±20%
units
Hz
V ac
V dc
A
A
μA
units
A
%
%
%
%
%
mS
mS

Summary of Contents

Page 1

... PART NUMBER: VMS-160 features ·industry standard 2x4 footprint 3 ·18 W/in power density ·universal input: 90264 V ac ·active PFC ·90% typical efficiency ·12 V auxillary fan output ·full medical and ITE safety approvals MODEL output voltage VMS-160 VMS-160- VMS-160- VMS-160- ALL 12 V fan aux ...

Page 2

... PART NUMBER: VMS-160 RELIABILITY parameter conditions/description MTBF 235K hours min convection, 300K hours typical with 400 LFM forced air (MIL-HDBK-217E-1, 75% of rated full load, 25°C ambient) PROTECTION CIRCUITS parameter conditions/description over current 130% max., auto recovery output over-voltage 130% max. short circuit the power supply will auto recover with no damage from a short on any output. GENERAL & ...

Page 3

... PART NUMBER: VMS-160 MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: open frame switching power supply phone phone 503.612.2300 fax fax 503.612.2383 page 12/2009 date www.v-infinity.com ...

Comments to this Datasheet