Datasheets»CUI»VEQ30-Q48-T515 Datasheet

VEQ30-Q48-T515 Datasheet

Download or read online CUI VEQ30-Q48-T515 DC/DC converter pdf datasheet.



Page
1 of 3
next
PART NUMBER: VEQ30 series
features
·30W isolated output
·efficiency to 84%
·200KHz switching frequency
·4:1 input range
·six-sided shield
·remote on/off control
model
input
number
voltage
VEQ30-Q24-S5
9-36VDC
VEQ30-Q24-S12
9-36VDC
VEQ30-Q24-S15
9-36VDC
VEQ30-Q24-D12
9-36VDC
VEQ30-Q24-D15
9-36VDC
VEQ30-Q24-T512
9-36VDC
VEQ30-Q24-T515
9-36VDC
VEQ30-Q24-T5125
9-36VDC
VEQ30-Q48-S5
18-72VDC
VEQ30-Q48-S12
18-72VDC
VEQ30-Q48-S15
18-72VDC
VEQ30-Q48-D12
18-72VDC
VEQ30-Q48-D15
18-72VDC
VEQ30-Q48-T512
18-72VDC
VEQ30-Q48-T515
18-72VDC
VEQ30-Q48-T5125
18-72VDC
th
20050 SW 112
Ave. Tualatin, Oregon 97062
DESCRIPTION: DC/DC converter
output
output
voltage
current
5VDC
5000mA
12VDC
2500mA
15VDC
2000mA
±12VDC
±1250mA
±15VDC
±1000mA
5/±12VDC
3000/±625mA
5/±15VDC
3000/±500mA
+5/+12/-5VDC
3000/600/1000mA
5VDC
5000mA
12VDC
2500mA
15VDC
2000mA
±12VDC
±1250mA
±15VDC
±1000mA
5/±12VDC
3000/±625mA
5/±15VDC
3000/±500mA
+5/+12/-5VDC
3000/600/1000mA
phone
phone 503.612.2300 fax
rev.
rev.
1 of 3
page
page
08/2007
date
date
input current
no load
full load
efficiency
20mA
1350mA
77%
20mA
1560mA
80%
20mA
1560mA
80%
25mA
1560mA
80%
25mA
1560mA
80%
25mA
1650mA
76%
25mA
1650mA
76%
25mA
1450mA
78%
15mA
670mA
78%
15mA
770mA
81%
15mA
770mA
81%
20mA
750mA
84%
20mA
750mA
84%
20mA
790mA
79%
20mA
780mA
80%
20mA
725mA
78%
fax 503.612.2382

Summary of Contents

Page 1

... VEQ30-Q24-T512 9-36VDC VEQ30-Q24-T515 9-36VDC VEQ30-Q24-T5125 9-36VDC VEQ30-Q48-S5 18-72VDC VEQ30-Q48-S12 18-72VDC VEQ30-Q48-S15 18-72VDC VEQ30-Q48-D12 18-72VDC VEQ30-Q48-D15 18-72VDC VEQ30-Q48-T512 18-72VDC VEQ30-Q48-T515 18-72VDC VEQ30-Q48-T5125 18-72VDC th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: DC/DC converter output output voltage current 5VDC 5000mA 12VDC 2500mA 15VDC 2000mA ±12VDC ± ...

Page 2

... PART NUMBER: VEQ30 series INPUT input voltage range input filter OUTPUT voltage accuracy single output dual output -output 3, 4 triple 5V 12V/15V -5V voltage balance (dual) transient response: single output: 25% step load change dual output: dualFL-1/2L ± 1% error band external trim adj. range ripple & ...

Page 3

... PART NUMBER: VEQ30 series DIMENSIONS (mm) DERATING CURVE 120% -25 100% 80% 60% Natural 40% Convection 20 Ambient Temperature( C) th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: DC/DC converter 71 100 phone phone 503.612.2300 fax rev page 08/2007 date fax 503.612.2382 ...

Comments to this Datasheet