SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• current monitoring and remote voltage adjustments (margin)
• short circuit, overload, over voltage and over temperature
protections
• optional IEC320 AC inlet or terminal block
• current sharing
RoHS
preset
MODEL
voltage
(Vdc)
VPM-S500-03R
3.3
VPM-S500-05R
5
VPM-S500-12R
12
VPM-S500-18R
18
VPM-S500-24R
24
VPM-S500-36R
36
VPM-S500-48R
48
Notes:
1. customer must specify output voltage
2. output is fully isolated
3. output voltage is measured at output power connector
4. 1% minimum load is required to maintain the ripple and regulation
5. Ripple & noise are measured at 20 MHz BW with 0.1 μF ceramic cap and a 22 μF electrolytic capacitors on the output
6. provides peak power of 900 W within 500 μs for all models
PART NUMBER KEY
output
output
voltage
1,2,3
current
min
max
max
(Vdc)
(Vdc)
(A)
2
3.3
80
5
6
80
12
15
41.67
16
21
31.25
22
30
22.73
31
41
16.13
42
55
10.42
VPM-S500 -
XX
Base Number Preset Output Voltage
cui.com
ripple
output
and noise
4,5
power
6
max
max
(% Vp-p)
(W)
75 mV
264
75 mV
400
±1
500
±1
500
±1
500
±1
500
±1
500
R
X
Current Sharing:
“blank” = N/A
I = available
date
08/28/2012
page 1 of 5
effi ciency
typ
(%)
70
75
80
83
83
83
83

Summary of Contents

Page 1

... SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY FEATURES current monitoring and remote voltage adjustments (margin) short circuit, overload, over voltage and over temperature protections optional IEC320 AC inlet or terminal block current sharing RoHS preset MODEL voltage (Vdc) VPM-S500-03R 3.3 VPM-S500-05R 5 VPM-S500-12R ...

Page 2

... CUI Inc SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description voltage frequency current at 90-264 Vac, full load inrush current at 230 Vac, full load, cold start Built-in ac fuse. A blown fuse usually indicates permanent input fuse damage to the power supply serviceable by factory only. ...

Page 3

... CUI Inc SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY SAFETY & COMPLIANCE parameter conditions/description primary to secondary for 3 seconds isolation voltage primary to transformer core for 3 seconds primary to earth ground for seconds safety approvals UL 60950-1 TUV EN 60950-1 EMI/EMC EN 55022 Class B conducted/radiated, EN 61000-3-(2,3), EN 55024, IEC 61000-4-(2,3,4,5,6,8,11) ...

Page 4

... CUI Inc SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY MECHANICAL parameter conditions/description dimensions 9.17 x 4.25 x 2.5 (232.92 x 107.95 x 63.5 mm) weight Two sets of 8 threaded mounting holes available on the enclosure. Mounting holes B: 6-32, maximum insertion depth of 0.2 inches. C: M4, maximum insertion depth of 0.2 inches. MECHANICAL DRAWING units: inches (mm) tolerance: inches: x.xx ± ...

Page 5

... CUI Inc SERIES: VPM-S500-R DESCRIPTION: AC-DC POWER SUPPLY REVISION HISTORY rev. 1.0 1.01 new template applied, V-Infi nity branding removed The revision history provided is for informational purposes only and is believed to be accurate. CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. ...

Comments to this Datasheet