SERIES: VMS-100
DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 100 W continuous power
• industry standard 3” x 5” footprint
• universal input (90~264 Vac)
• single output from 5 to 48V
• no load power consumption < 0.5W
• over voltage and short circuit protections
• full medical approvals
• built-in active PFC function
• built-in remote sense function
• no minimum load required
• efficiency up to 91%
RoHS
MODEL
VMS-100-5
VMS-100-9
VMS-100-12
VMS-100-15
VMS-100-18
VMS-100-24
VMS-100-28
VMS-100-36
VMS-100-48
Notes:
1. VMS-100-5: Measured at 20MHz, with 0.1μF ceramic and 220μF electrolytic capacitors
2. All other models: Measured at 20MHz, with 0.1μF ceramic and 10μF electrolytic capacitors
PART NUMBER KEY
output
output
voltage
current
max
(Vdc)
(A)
5
20
9
11.2
12
8.4
15
6.7
18
5.6
24
4.2
28
3.6
36
2.8
48
2.1
VMS-100 -
XX
Base Number
Output Voltage
cui.com
output
ripple and
1,2
power
noise
max
max
(W)
(mVp-p)
100
100
100
90
100
120
100
150
100
180
100
240
100
280
100
360
100
480
date
08/22/2012
page 1 of 4
effi ciency
typ
(%)
85
88
89
89
90
91
91
91
91

Summary of Contents

Page 1

... RoHS MODEL VMS-100-5 VMS-100-9 VMS-100-12 VMS-100-15 VMS-100-18 VMS-100-24 VMS-100-28 VMS-100-36 VMS-100-48 Notes: 1. VMS-100-5: Measured at 20MHz, with 0.1μF ceramic and 220μF electrolytic capacitors 2. All other models: Measured at 20MHz, with 0.1μF ceramic and 10μF electrolytic capacitors ...

Page 2

... CUI Inc SERIES: VMS-100 DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description voltage frequency inrush current at 240 Vac OUTPUT parameter conditions/description line regulation low line to high line, full load load regulation 10% to 100% full load temperature coeffi cient hold-up time adjustability switching frequency ...

Page 3

... CUI Inc SERIES: VMS-100 DESCRIPTION: AC-DC POWER SUPPLY DERATING CURVES MECHANICAL DRAWING units: mm[in] TOLERANCE: mm: ±0.5 inch: ±0.02 5.70 0.224 76.20 3.000 CN1 1 AC Line 2 No pin 3 AC Neutral Molex 5227 connector 1.60 0.063 3.00 0.118 max output power vs. ambient temperature 100 80 60 100 LFM 20 LFM (natural convection) ...

Page 4

... CUI Inc SERIES: VMS-100 DESCRIPTION: AC-DC POWER SUPPLY REVISION HISTORY rev. 1.0 1.01 The revision history provided is for informational purposes only and is believed to be accurate. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation ...

Comments to this Datasheet