Datasheets»Panasonic Corporation»ACV3101211012 Datasheet

ACV3101211012 Datasheet

Download or read online Panasonic Corporation ACV3101211012 POWER/SIGNAL RELAY pdf datasheet.



Page
1 of 5
next
Products with diode inside
are discontinued in 2014.
Products with diode inside
are discontinued in 2014.
mm
inch
15
22.5
.591
.886
15.7
.618
Micro ISO 1a type
Micro ISO 1c type
Products to be discontinued.
SPECIFICATIONS
Contact
Arrangement
1 Form A
Contact material
Ag alloy (Cadmium free)
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
N.O.: Max. 0.2 V
Contact voltage drop
(at 20 A)
Nominal switch-
N.O.: 20 A 14 V
ing capacity
DC
Max. carrying
Rating
current
N.O.: 20 A 12 V
(Continuous,
DC
at 85C 185F)
Min. switching
capacity
#1
Mechanical
Expected
(at 120 cpm)
life (min.
Electrical
operation)
(at rated load)
Coil
Nominal operating power
0.8 W, 1.0 W (with resistor inside type)
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
ds_61214_en_cv: 030412D
Automotive low profile
micro-ISO relay
FEATURES
• Low profile:
22.5 mm(L)15 mm(W)15.7 mm(H)
.886 inch(L).591 inch(W).618 inch(H)
• Low temperature rise
Terminal temperature has been reduced
compared with using our conventional
product
• Low sound pressure level
Noise level has been reduced
approx.10dB compared with using our
conventional product.
• Wide line-up
Micro ISO terminal types and resistor and
diode inside type.
• Plastic sealed type
Plastically sealed for automatic cleaning.
Characteristics
1 Form C
Max. operating speed
(at nominal switching capacity)
Initial insulation resistance*
Typ. 3 m
Initial breakdown
N.O.: Max. 0.2 V
voltage*
3
(at 20 A switching)
N.C.: Max. 0.5 V
Operate time*
(at 10 A switching)
(at nominal voltage) (at 20C 68F)
N.O.: 20 A 14 V
Release time*
DC
(at nominal voltage) (at 20C 68F)
N.C.: 10 A 14 V
DC
N.O.: 20 A 12 V
Shock resistance
DC
N.C.: 10 A 12 V
DC
Vibration resistance
1 A 12 V DC
Conditions in case of opera-
Min. 10
6
tion, transport and storage*
(Not freezing and condensing
Min. 10
5
*
1
at low temperature)
Mass
Remarks
*
1
At nominal switching capacity, operating frequency: 2s ON, 2s OFF
*
Measurement at same location as “Initial breakdown voltage” section.
2
*
3
Detection current: 10mA
*
4
Excluding contact bounce time.
Half-wave pulse of sine wave: 11 ms; detection time: 10 s
*
5
*
6
Half-wave pulse of sine wave: 6 ms
Detection time: 10 s
*
7
*
Time of vibration for each direction;
8
Y
X
Z
*
9
Refer to “6. Usage, Storage and Transport Conditions“ in
ENVIRONMENT section in Relay Technical
Please inquire if you will be using the relay in a high temperature atmosphere.
CV (ACV)
CV RELAYS (ACV)
• Compact and high-capacity 20A load
switching
N.O.: 20A 14V DC, N.C.: 10A 14V DC
(Max. carrying current: at 85C 185F)
TYPICAL APPLICATIONS
• Headlights
• Magnetic clutches
• Radiator fans
• Blowers
• Fog lamps
• Tail lights
• Heaters
• Defoggers
• Horns
• Condenser fans, etc.
Min. 20M
2
(at 500 V DC)
Between open contacts
500 Vrms for 1min.
Between contacts and coil
500 Vrms for 1min.
4
Max. 10ms (initial)
Max. 10ms (initial)
4
Max. 15ms (initial)
(with diode inside type)
Functional*
5
Min. 100 m/s
Destructive*
6
Min. 1,000 m/s
10 Hz to 100 Hz,
Functional*
7
Min.44.1 m/s
10 Hz to 500 Hz,
Destructive*
8
Min.44.1 m/s
Ambient
–40C to +85C
temp
–40F to +185F
9
Humidity
5% R.H. to 85% R.H.
Approx. 15.0g
X, Y, Z direction: 4 hours
AMBIENT
Information.
15cpm
2
{10 G}
2
{100 G}
{4.5 G}
2
{4.5 G}
2
.53 oz
1
Specifications of Panasonic Corporation ACV3101211012
Manufacturer Series:
ACV
Relay Type:
POWER/SIGNAL RELAY

Summary of Contents

Page 1

Products with diode inside are discontinued in 2014. Products with diode inside are discontinued in 2014. mm inch 15 22.5 .591 .886 15.7 .618 Micro ISO 1a type Micro ISO 1c type Products to be discontinued. SPECIFICATIONS Contact Arrangement 1 ...

Page 2

CV (ACV) ORDERING INFORMATION Ex Product name Contact arrangement Form Form A Note: Standard packing; Carton (Tube): 50 pcs.; Case: 200 pcs. D: with diode inside TYPES Coil voltage (DC) Contact arrangement ...

Page 3

Products with diode inside are discontinued in 2014. REFERENCE DATA 1. Coil temperature rise (20A) Point measured: Inside the coil Contact carrying current: 20A Coli applied voltage: 13.5V 180 150 20A 120 ...

Page 4

CV (ACV) 4-(2). Electrical life test (Lamp load) Sample: ACV12212, 3pcs. Load: 55Wx4, inrush: 90A/steady: 20A, lamp actual load Switching frequency: (ON : OFF 1s : 14s) Ambient temperature: Room temperature Circuit 13.5VDC 55W 55W 55W Load current waveform ...

Page 5

Products with diode inside are discontinued in 2014. Cautions regarding the protection element 1. Part numbers without protection elements • models When connecting a coil surge protection circuit to these relays, we recommend a Zener diode with a ...

Comments to this Datasheet