Table 11. Current State Bank n, Command to Bank m
Current State
CS#
RAS#
L
L
Read
L
H
(With Auto
L
H
Precharge)
L
L
L
L
Write
L
H
(With Auto
L
H
Precharge)
L
L
Note :
68. This table applies when CKE
was HIGH and CKE
n-1
69. This table describes alternate bank operation, except where noted; i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m
(assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below.
70. Current state definitions: Idle: The bank has been precharged, and t
bursts/accesses and no register accesses are in progress. Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated.
Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated.
Read w/Auto Precharge Enabled: Starts with registration of a READ command with auto precharge enabled, and ends when t
the idle state. Write w/Auto Precharge Enabled: Starts with registration of a WRITE command with auto precharge enabled, and ends when t
bank will be in the idle state.
71. AUTO REFRESH, SELF REFRESH and LOAD MODE REGISTER commands may only be issued when all banks are idle.
72. A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only.
73. All states and sequences not shown are illegal or reserved.
74. READs or WRITEs to bank m listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled.
75. CONCURRENT AUTO PRECHARGE: Bank n will initiate the auto precharge command when its burst has been interrupted by bank m’s burst.
76. Burst in bank n continues as initiated.
77. For a READ without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later.
78. For a READ without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered.
DQM should be used twwo clock prior to the WRITE command to prevent bus contention.
79. For a WRITE without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered,
with the data-out appearing CAS latency later. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m.
80. For a WRITE without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered.
The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m.
81. For a READ with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later.
The PRECHARGE to bank n will begin when the READ to bank m is registered (Figure 25.) .
82. For a READ with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered. DQM should be
used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered (Figure 26. ).
83. For a WRITE with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out
appearing CAS latency later. The PRECHARGE to bank n will begin after t
be data-in registered one clock prior to the READ to bank m(Figure 27. ).
84. For a WRITE with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered.
The PRECHARGE to bank n will begin after t
WR
clock prior to the WRITE to bank m (Figure 28. ).
Rev0.3, May., 2010
[68.69.70.71.72.73.]
.
CAS#
WE#
H
L
ACTIVE (Select and activate row)
L
H
READ (Select column and start new READ burst)
L
L
WRITE (Select column and start WRITE burst)
H
L
PRECHARGE
H
H
ACTIVE (Select and activate row)
L
H
READ (Select column and start READ burst)
L
L
WRITE (Select column and start new WRITE burst)
H
L
PRECHARGE
is HIGH and after t
has been met (if the previous state was self refresh).
n
XSR
has been met. Row Active: A row in the bank has been activated, and t
RP
is met, where t
begins when the READ to bank m is registered. The last valid WRITE to bank n will
WR
WR
is met, where t
begins when the WRITE to bank m is registered. The last valid WRITE to bank n will be data registered one
WR
FMS1616LAx-xxEx
Command(Action)
[74.75.81.]
[74.75.82.]
[76.]
[74.75.83.]
[74.75.84.]
[76.]
has been met. No data
RCD
has been met. Once t
is met, the bank will be in
RP
RP
has been met. Once t
is met, the
RP
RP